Citation Atlas
29 CFR Part 1926
1926.306
Air receivers

1926.306 Compressed Air Tanks: citations, penalties and recently cited employers

Data as of October 5, 2026 · citations issued Oct 5, 2025 to Oct 5, 2026

Compressed air receivers used in construction, such as tanks on air compressors, must be built and installed according to the applicable boiler and pressure vessel code. Receivers must be installed so drains, handholes, and manholes are accessible, and must be equipped with drain valves that are opened frequently to remove water. Safety valves, pressure gauges, and indicating devices must be maintained and tested.

17inspections cited
17alleged violation items
$0median initial penalty per item
$0median current penalty per item
0%of items contested

What the standard requires

Hazards it addresses

Cited at construction sites and shops using portable or stationary air compressors.

Plain-language summary written for this site; it is not the regulatory text and not legal advice. Read the official text at eCFR.

Citations by month

Inspections with citations issued, by month of issuance. Hatched months are incomplete: citations reach the public data about a month after issuance.

Most-cited paragraphs

ParagraphWhat it coversItemsInspectionsMedian initial penalty
1926.306(b)(3)(i)1515$0
1926.306(b)(3)(iii)22$218

Penalties

Across 17 alleged items, OSHA and state-plan offices proposed $19,278 in initial penalties. The current total in the public data is $17,060, 12% lower after settlements, contests and amendments.

By violation type: Other-than-serious 71%; Serious 29%.

Citations by state

StateInspections citedItemsInitial penaltiesCurrent penalties
North Carolina1212$3,000$3,000
Maryland22$437$275
Arizona11$0$0
Florida11$4,256$2,200
Louisiana11$11,585$11,585

By industry

Recently cited establishments

About these records. Citations list alleged violations and proposed penalties. Employers can contest them, and many are reduced or withdrawn in settlement. Each row shows the original and the current penalty and a status label derived from the public data as of October 5, 2026. Check the linked osha.gov page for the official record.

EstablishmentLocationIssuedAlleged itemsInitial penaltyCurrent penaltyStatus and deadlinesSource
Name withheld (individual) Jamestown, NC Aug 26, 2026 1 $0 $0 Final orderAbatement due Aug 31, 2026 osha.gov
Junior's Framing, LLC Kernersville, NC Aug 25, 2026 1 $0 $0 Final orderAbatement due Aug 31, 2026 osha.gov
Pig Roofing, LLC Jacksonville, FL Jul 24, 2026 1 $4,256 $2,200 Informal settlement osha.gov
Solano Construction, LLC Cambridge, MD Jul 14, 2026 1 $0 $0 OpenAbatement due Jul 22, 2026Contest deadline ~Aug 4, 2026 (est.) osha.gov
A-G Constructions, LLC Winston Salem, NC May 26, 2026 1 $0 $0 Final orderAbatement due Jun 1, 2026 osha.gov
Jca Unlimited Construction LLC Winston Salem, NC May 26, 2026 1 $0 $0 Final orderAbatement due Jun 1, 2026 osha.gov
Toledo Construction - Framing, LLC Summerfield, NC May 15, 2026 1 $0 $0 Informal settlementAbatement due May 19, 2026 osha.gov
Core Built Construction LLC Kernersville, NC May 12, 2026 1 $0 $0 Final orderAbatement due May 18, 2026 osha.gov
Name withheld (individual) Winston Salem, NC Apr 6, 2026 1 $0 $0 Final orderAbatement due Apr 10, 2026 osha.gov
Svbros Construction LLC Oakland, MD Mar 27, 2026 1 $437 $275 Informal settlementAbatement due Apr 29, 2026 osha.gov
Name withheld (individual) Kernersville, NC Feb 27, 2026 1 $0 $0 Final orderAbatement due Mar 3, 2026 osha.gov
Name withheld (individual) Kernersville, NC Feb 26, 2026 1 $0 $0 Final orderAbatement due Mar 2, 2026 osha.gov
Marcelo Mota Sangabriel Lewisville, NC Dec 29, 2025 1 $0 $0 Final orderAbatement due Jan 2, 2026 osha.gov
Name withheld (individual) Greensboro, NC Nov 13, 2025 1 $0 $0 Informal settlementAbatement due Nov 17, 2025 osha.gov
Gso Contracting, Inc. Summerfield, NC Oct 21, 2025 1 $3,000 $3,000 Final orderAbatement due Oct 27, 2025 osha.gov
Semper FI Industrial Coatings Shreveport, LA Dec 22, 2025 1 $11,585 $11,585 Final orderAbatement due Sep 8, 2025 osha.gov
Luis Alberto Bueno, a Single Man dba Los Bueno Construction LLC Scottsdale, AZ Nov 5, 2025 1 $0 $0 Status not determinableAbatement due Aug 18, 2023 osha.gov
The 17 most recent inspections citing 1926.306. Penalties shown are for the items under this standard only.

Often cited together

Questions

What does OSHA standard 1926.306 require?

Compressed air receivers used in construction, such as tanks on air compressors, must be built and installed according to the applicable boiler and pressure vessel code. Receivers must be installed so drains, handholes, and manholes are accessible, and must be equipped with drain valves that are opened frequently to remove water. Safety valves, pressure gauges, and indicating devices must be maintained and tested.

How often was 1926.306 cited in the last 12 months?

In the public data as of October 5, 2026, 1926.306 (Compressed Air Tanks) appeared in 17 inspections with citations issued between Oct 5, 2025 and Oct 5, 2026, covering 17 alleged violation items.

Which part of 1926.306 is cited most?

1926.306(b)(3)(i) was the most-cited paragraph, with 15 items.

Which states cite 1926.306 most often?

The most citations under 1926.306 in this period were issued in North Carolina, Maryland, Arizona.

What is the typical penalty for a 1926.306 violation?

The median initial (proposed) penalty per item was $0; the median current penalty after settlements and amendments was $0. Totals: $19,278 proposed, $17,060 current. Penalties vary by violation type, employer size and history, and State Plans set their own amounts.

Are 1926.306 citations final?

Not necessarily. A citation is an allegation until it becomes a final order. 0% of these items were contested, and many others were changed in settlements. Each listing shows its current status and a link to the official record.